Dynamic Precision Measuring Device

NEW SELBER ⅢOption Board

<span>NEW SELBER Ⅲ</span>Option Board

Specifications

Please purchase empty slots for 6 channels according to your needs.

Name BDC Board
Model RO-3011B
Measurement resolution RM-3000:1μm RM-3000J:0.1μm
Measuring range 500-2000μm
Linear range 700-1700μm
Linearity 1% of F.S.
Temperature drift
*In case of precision compensation
Sensor part: 0.1μm/℃
Amplifier part: 1.0μm/℃
Operating Temperature Limit 5-45℃ (No Condensation)

*The specifications and the contents described in this instruction manual are subject to change without prior notice.


Name Long range board
Model RO-3011D
Measuring range 2,000-10,000μm
Linear range 2,000-10,000μm
Linearity 1% of F.S.
Repeatability ±10μm
Response frequency 500Hz
Temperature drift
*In case of precision compensation
Sensor part: 1μm/℃
Amplifier part: 10μm/℃
Operating Temperature Limit 5-45℃ (No Condensation)

*The specifications and the contents described in this instruction manual are subject to change without prior notice.

Name Load board
Model RO-3011L
Measuring range 0.000-999.999kN
Measurement accuracy ±1% of F.S.
Response frequency 10KHz or less
Delay time 50μsec
Resolution 0.001kN Min. *Depending on the setting full scale
Applied voltage DC10V
Operating Temperature Limit 5-45℃ (No Condensation)
Sensor
(Please prepare separately)
Corresponding to the following sensor output
0.5mV/V
1.0mV/V
1.5mV/V
2.0mV/V

*The specifications and the contents described in this instruction manual are subject to change without prior notice.

Name Relate Board
Model RO-3011R
Measurement resolution RM-3000:1μm RM-3000J:0.1μm
Measuring range 500-2000μm
Linear range 700-1700μm
Linearity 1% of F.S.
Temperature drift
*In case of precision compensation
Sensor part: 0.1μm/℃
Amplifier part: 1.0μm/℃
Operating Temperature Limit 5-45℃ (No Condensation)

*The specifications and the contents described in this instruction manual are subject to change without prior notice.

Name Temperature board
Model RO-3011T
Measurement accuracy ±3℃ * Does not include sensor drift
Measuring range -5-300℃
Resolution 1℃
Operating Temperature Limit 5-45℃ (No Condensation)
Attached sensor K type thermocouple (exposed type) heat resistance 150℃, cable length 5m

*The specifications and the contents described in this instruction manual are subject to change without prior notice.

Name Voltage/Current Board
Model RO-3011V
Measurement resolution
*By range switching
±10Vrange:0.01V
±1Vrange:0.001V
±0.1Vrange:0.001V
20mArange:0.01mA
Measurement accuracy ±3% of F.S.
Response frequency 100KHz or less
Input resistance Voltage input: 200kΩ Current input: 200Ω
Absolute maximum rating Voltage input: 15V Current input: 30mA
Power supply for sensor DC24V 200mA Max.
Operating Temperature Limit 5-45℃ (No Condensation)

*The specifications and the contents described in this instruction manual are subject to change without prior notice.

Name Shock Board
Model RO-3011S
Measurement resolution 0.1G Min. (Depending on the setting full scale)
Measuring range ±300G
Measurement accuracy ±1% of F.S.
Sensor applied voltage DC20V constant current 1mA
Operating Temperature Limit 5-45℃ (No Condensation)

*The sensor is optional (sold separately).
*The specifications and the contents described in this instruction manual are subject to change without prior notice.

Inquiry

Please wait until input screen displayed.

If input screen is not displayed, please email to sales-nara@rikenkeiki.co.jp.